2024年12月3日
Number of zones | 6 heating zones / 1 cooling zone |
---|---|
Heating method | Upper and lower hot air + far infrared heating method |
Maximum set temperature | Top 350℃ / Bottom 350℃ |
Effective board width | 50~160mm |
Transport method (selectable) | Pin chain transport/mesh transport |
Transport speed | 0.1~0.5m/min |
Part effective height | Top 5mm / Bottom 5mm |
Oxygen concentration meter | Standard equipped |
Supported languages | Japanese/English/Chinese/Korean |
PC outlet | 1 piece (100V) |
Board mounting allowance | 4mm |
Pass line | 900±20mm |
Input power supply | AC200V 3φ 19kVA 55A |
Dimensions of the device *The numbers in parentheses are for mesh transport | L2,180(2,270)×D960×H1,380mm |
Device weight | 600kg |
Expanded effective board width (up to 220mm) |
Flux recovery device |
Automatic width adjustment mechanism |
Overheating prevention device |
Board drop sensor |
Oxygen concentration controller |
N2 all zone supply |
Oxygen concentration all zone sampling |
Low oxygen concentration specifications (100ppm or less) |
Cooling reinforcement unit/cooling chiller |
UPS (uninterruptible power supply) |
Power transformer |
Entrance/exit conveyor extension |
Circulation fan stop detection |
Hood interlock |
Emergency stop button position change |
Reflow checker (profile measurement unit) |
Various types of cooling conveyors and transport conveyors |
Paint color change |